LG Refrigerators

Error Code E It

Abnormal Ice Maker Unit — Ice maker step motor fault, Hall IC, or wire short. Fault in motor driving circuit.

Moderate

Address soon - your appliance may not work properly

Also displayed as: E It

How to Fix

  1. 1

    Step 1: Check if connector is disconnected or loose between Main PCB and ice maker motor.

  2. 2

    Step 2: If disconnected, reconnect or repair the connector.

  3. 3

    Step 3: Check ice maker motor housing resistance at CON1 26th~28th pin. Expected: 19.7 ohm. If not, change the ice maker (IM) unit.

  4. 4

    Step 4: Push the I/M test key and check voltage in I/M test mode at CON1 18th~23rd pin. Expected: between 0~5V (varying). If voltage is not correct, change the IM unit or replace Main PCB.

  5. 5

    Step 5: If all values are correct, explain to customer.

This Error Applies To

LG LHSXS2706 Series Refrigerators

Service manual exact match: LHSXS2706SService manual exact match: LHSXS2706VService manual exact match: LHSXS2706DService manual exact match: LHSXS2706W